What is Triaxial Testing-Controls

Typical triaxial tests involve confining a sealed spherical soil instance, with a height-to-periphery rate of 21, into a pressurized cell to pretend defined stress conditions. The instance is also sheared until failure which leads to the determination of its shear strength parcels.

In this article, we will explore all aspects of Triaxial Testing including:

  • Define what triaxial testing
  • Outline why you should perform these tests
  • Explain different types of triaxial tests and methods
  • Go through the typical test procedures
  • Explore details of the main components required
  • Go through the typical available configurations

What is Triaxial Testing?

A triaxial shear test is a common method to measure the mechanical properties of many deformable solids, especially soil (e.g. sand, clay) rock, and other granular materials or powders. Source

Typical triaxial tests involve confining a sealed cylindrical soil specimen, with a height-to-diameter ratio of 2:1, into a pressurized cell to simulate defined stress conditions. The specimen is then sheared until failure which leads to the determination of its shear strength properties. The specimen will usually be saturated first, then consolidated, and finally sheared, mostly under compressive conditions.

However, some further tests can also be performed with the correct equipment. For example, the top cap with the vacuum attachment (necessary to create a rigid connection between the load frame, the load cell, and the specimen) allows triaxial tests under extension conditions, Stress path or K0 tests to be carried out. Tests must be performed on undisturbed, remolded, or compacted specimens that are subjected to different stress and drainage conditions (see Figures 1 and 2, below) to simulate in-situ stresses. Specimen sizes can range from 38mm to 100mm, although considerably larger samples can be used, provided the correct equipment is used.

                                  Figure 1 – Stress condition in a standard triaxial test.
                                             Figure 2 – Total/effective stress

σ1 or σV = Axial / Vertical Stress
σ3 or σh = Confining pressure / Horizontal Stress
u = Pore water Pressure (PWP)

Why use Triaxial Testing?

The triaxial test is one of the most versatile, comprehensive, and widely performed in geotechnical engineering. Table 1, below, lists the most common engineering issues that triaxial tests can assess.

Field problem Test Type
Tunneling UU – Quick triaxial – CD Effective stress
Landfill liners UU – Quick triaxialCU – CD Effective stressTriaxial permeability
Foundation design UU – Quick triaxial -CD Effective stress
Earth dams UU – Quick triaxialCU Effective stressTriaxial permeability
Slope stability UU – Quick triaxial -CD Effective stress
Cut slope failure CU Effective stress
                   Example of different stress conditions induced by shallow foundations.
Example of different stress conditions induced by a combination of shallow foundations and excavation.

Some other tests are easier to perform, like the standard direct shear test, but these tests aren’t as comprehensive as they don’t allow the control of the instance’s drainage as well as take severance pressure measures. In addition, a triaxial test helps to calculate important soil parameters such as cohesion( c ’), internal angle of disunion( φ ’) and shear strength to be determined. The triaxial test can also be used to determine other variables similar to the shear stiffness G, and permeability.

Triaxial Test Types

Three fundamental triaxial tests can be conducted in the laboratory, each allowing the soil response for differing engineering applications to be observed:

  • Unconsolidated Undrained test (UU), also called quick triaxial
  • Consolidated Undrained Test (CU)
  • Consolidated Drained test (CD)

UU triaxial tests are also called total stress tests and CU/CD triaxial tests are also called effective stress tests. It is common for UU triaxial tests to be used for short-term engineering problems and CU and CD triaxial to assess long-term engineering problems.

Unconsolidated Undrained (UU)

With this method, the shear strength is measured in terms of total stress. The soil specimen is not allowed to consolidate and must maintain its original structure and water content so that its compressive strength depends on the level of geostatic stress in the field.

Tests are often carried out on three specimens obtained from the same sample, each subjected to a different confining pressure. Provided that the soil is fully saturated, the shear strength will be the same for each test and is known as “undrained shear strength”. An additional test called Unconfined Compressive Strength (UCS) can also be undertaken with a triaxial system, simply setting the confining pressure to zero.

Unconsoidated Undrained

Consolidated Undrained (CU)

Here, the shear strength is measured in terms of effective stress. The specimen is saturated and allowed to consolidate (soil consolidation is the process that changes its structure and water content) at the required confining pressure. Once consolidated, the specimen is subjected to a controlled application of load, during which no drainage is allowed so that pore pressure can be measured.

Since the shear strength is affected by the effective stresses, by testing a set of three specimens at different confining pressures, it is possible to define the failure envelope according to Coulomb’s model and define the parameters c’ and φ’, as well as evaluating the undrained shear strength.

Consolidated Undrained

Consolidated Drained (CD)

With this method, the shear strength is measured in terms of effective stress. The specimen is saturated and allowed to consolidate2 at the required confining pressure. Once consolidated, the specimen is subjected to a controlled application of load, during which moisture is allowed to drain without the possibility of pore pressure building up.

Since the shear strength is affected by the effective stresses, by testing a set of three specimens at different confining pressures, it is possible to define the failure envelope according to Coulomb’s model and define the parameters c’ and φ’.

UU triaxial tests are quick, take under 30 minutes to perform, and usually do not go through a saturation or consolidation stage as the test only consists of a shear stage. Whereas, the CU and CD triaxial tests normally start during the saturation stage, which then leads to a consolidation stage. CU and CD triaxial tests also take significantly longer to perform, sometimes several days, weeks, or even months before reaching completion.

The CD triaxial test usually takes the longest, as during the shear stage, pore pressure is not allowed to build up, resulting in very low strain rates. CU triaxial tests are faster as pore water pressure (PWP) is allowed to increase and the excess PWP is measured throughout the shear stage.

Consolidated Drained

Typical Test Stages

Before the test: specimen and system preparation
The test specimen must be obtained from a soil sample before being placed into the triaxial cell. For cohesive soils, this may involve trimming undisturbed specimens extruded from Shelby tubes or cut from block samples. However, for granular soils, you will need to prepare the specimen directly on the pedestal using a split-part mold. Below is an example of a mold and former:

Two-part split former with vacuum attachment for preparation of remolded specimens
These molds are used for the preparation of non-cohesive specimens by compaction or vibration — as is required for triaxial testing. The mold must be placed directly on the triaxial cell’s pedestal. To ensure the membrane adheres to the mold’s inner wall, a vacuum is applied to obtain the correct diameter of the remolded specimen.

Hand sampler with cutter, dolly, and receiver
Used for the preparation of undisturbed specimens from cohesive samples for triaxial tests.

Two-part split mold
Used for trimming the ends of undisturbed specimens. Once the specimen preparation is complete, we are ready to conduct the triaxial test, which comprises three main stages:

Stage 1 – Saturation

The saturation process ensures that all voids within a test specimen are filled with water and that the pore pressure transducer and drainage lines are properly de-aired. The most common saturation method is to apply an incremental increase of the cell and back pressure into the specimen. This process gradually raises both the cell and back pressure which dissolves any air that may be present in the specimen.

During this process, the pore pressure coefficient B is calculated to determine the degree of saturation. These steps are repeated until the sample is saturated. Most standards state that a B value greater than 0.95 indicates that a specimen is sufficiently saturated. The B value is calculated as a ratio between ∆u = Change in pore pressure and ∆σ3 = Change in Confining Pressure; B= ∆u/∆σ3

Saturation testing

Stage 2 – Consolidation

After saturation, the specimen is normally consolidated to a stress condition representative of its in-situ condition. The consolidation is normally isotropic – stresses applied vertically and horizontally to the sample are the same (σ3 = σ1). However, consolidation can also be anisotropic where σ3 ≠ σ1. In this case, tests are commonly abbreviated to CIU (Consolidated Isotropic Undrained) or CAU (Consolidated Anisotropic Undrained). Specimen consolidation is typically conducted by increasing the cell pressure whilst maintaining a constant back pressure (often equal to the pore pressure reached during the final saturation B-check).

Once the consolidation process has started, the excess pore pressure in the specimen will start to dissipate as the consolidation process drains the water from the specimen, decreasing its volume. This process is continued until the volume change ΔV of the specimen is no longer significant, and at least 95% of the excess pore pressure has dissipated. At the end of the consolidation stage, a suitable rate of strain for shearing the specimens is also calculated. For more information, read our blog article dedicated to consolidation testing.

Consolidation testing

Stage 3 – Shear

Also called the failure or compression stage, the shear test involves the specimen being sheared by gradually increasing the axial force (σ1) (with a constant axial strain rate), maintaining the confining pressure (σ3), until the sample fails (failure usually occurs within 20% of the axial strain). Depending on the engineering issues that need to be simulated during the shear stage, the drainage conditions applied to the specimen will determine if a drained or undrained test is to be carried out.

In an undrained test, the specimen is not allowed to drain – its volume will not change during this stage but will change in shape, leading to a pore pressure development that will be measured. If drainage is allowed, water will drain from the specimen during the shear stage, enabling the volume and the shape of the sample to change while preventing the pore pressure from changing.

As well as the shear strength being determined, the values of cohesion (c’) and phi (φ’) can also be determined using the Mohr Circle and Stress Path plots. At the end of shearing, you will need to dismantle the system and carry out post-test specimen measurements, such as the final moisture content.

Shear testing

Main Components of a Triaxial System

To perform a triaxial test, the system requires several components:

1. Load frame: The load frame applies axial deformation to a specimen and can be shared with more than one triaxial cell. In this configuration, saturation and consolidation stages can be performed at the same time and the shear stage can be run one per time under the load frame (e.g. configuration with one frame and three triaxial cells). When the number of frames equals the number of triaxial cells, load frames can be considered as dedicated load frames whereby additional advanced tests, such as Stress Path and K0 test can be performed.

2. Triaxial cells and accessories for triaxial cells: Triaxial cells are available for various sample sizes and pressure ratings. The cell houses the triaxial specimen and is pressurized at all times during all test stages. The specimen is sealed inside a rubber membrane and then surrounded with water to create pressure that is then used to apply stress to the sample (σ3).

Back pressure can be added to saturate the sample if required. During the shearing stage, the axial force on the specimen increases and it is measured by the load cell, as well as the deformation measured by the displacement transducer, and the pore pressure in the sample can be measured, if required. Volume change of the sample is measured from the back pressure line using a volume change unit or pressure/volume controller.

Triaxial and accessories for triaxial

3. Pressure system: Three types of systems are available for applying cell and back pressure inside a triaxial system:

Air/water interface – comprising:

  • A distribution panel – designed to correctly distribute the de-aired water to the various equipment forming the triaxial system. Supplied with a pressure regulator for each pressure line (usually two), it also allows a technician to adjust the pressure coming from the air compressor via a pressure gauge.
  • A bladder cylinder – providing an interface between compressed air and water in your triaxial system. It is fitted with a rubber bladder that transforms the air pressure into both the water pressure used in the cell and the back pressure required for the triaxial test.
  • Air compressor – used for generating compressed air.

Pressure volume/controller:

This works by applying pressure to water cylinders and generating the required cell pressure and back pressure without any need for compressed air. A stepper motor drives the unit allowing it to measure the volume change throughout all stages of triaxial testing. To facilitate the correct distribution of the water to all the equipment before starting the test, the addition of a distribution panel is recommended.

Oil/water interface: 

This apparatus is typically used for generating confining pressure (cell pressure) in a UU test where no back pressure and measures of volume change are required. It provides a constant water pressure by using an adjustable spring-type-dead-weight pressure system connected in line with a pump and oil/water vessel.

Analog measuring devices electronic:

Measuring devices: Several sensors can be used that monitor the different variables involved in testing:

  • Load sensors – measure the change in axial load applied to the specimen during the shear stage. It could be a load ring or an external or submersible load cell.
  • Displacement sensors – measure the change in height of a specimen (and hence axial strain εa). It can come as a mechanical dial gauge, digital dial gauge, or potentiometric transducers.
  • Volume change sensors – used in CU and CD tests to measure the volume of water going into or out of the specimen, as well as the volume change of the specimen during the test. This may be a burette or automatic volume change device. When used with a pressure/volume controller, volume can also be measured with this type of sensor.
  • Pore water pressure – used in CU and CD tests to measure the change in pore water pressure inside the specimen. This may be a pressure manometer or pore pressure transducer.

4. Data acquisition: A datalogger converts analog readings obtained from the load cell, pore water pressure, and axial displacement transducers to digital data that is then stored. It can be either built-in with your standard triaxial system or supplied as an external unit. When used with an automatic system, data acquisition can also manage and control all devices needed for triaxial testing with a PC and dedicated software.

5. De-airing system: Removes dissolved air from water, necessary for CU/CD testing.

6. Data processing and reporting: The main International Standards demand that data be processed to produce dedicated test reports.

Triaxial Testing Configuration

Triaxial Systems with analog measurements are the ideal basic solution to perform standard triaxial tests, such as effective and total stress, for laboratories that don’t require digital measurement. All data acquisition and test management are made in manual mode.

Triaxial Systems with automatic built-in data acquisition are the simplest compact solution for standard triaxial testing (effective and total stress). It can be equipped with a standard air/water interface pressure system or with automatic pressure/volume controllers. No requirement for external data acquisition and/ or PC.

Triaxial Systems with automatic external data acquisition is an expandable compact solution for standard triaxial testing (effective and total stress) and for many other soil tests. It can be equipped with a standard air/water interface pressure system or with automatic pressure/volume controllers. Data acquisition can be shared with other soil testing equipment (such as for consolidation and shear) acquisition and/or PC.

Fully Automatic PC controlled Triaxial System AUTOTRIAX EmS: the advanced triaxial testing system that can automatically and simultaneously run up to 6 independent tests without any human intervention.

All-in-one fully automatic Triaxial testing system – Autotriaxqube: all-in-one automatic triaxial testing system integrating the many components of triaxial testing into one, single compact system.

 

Leave a Comment